4130 Chromoly Pipe Suppliers
Buyers ask for "4130 pipe" and "4130 tube" interchangeably, but the two are sized differently. Pipe is ordered by nominal pipe size and schedule; tube is ordered by actual outside diameter and wall. Getting this right avoids ordering the wrong size.
Pipe Sizing vs Tube Sizing
Tube is specified by its real outside diameter and wall, for example 1.500" OD × 0.095" wall. Pipe is specified by a nominal pipe size (NPS) and a schedule. For NPS 1/8 to NPS 12 the nominal size is not the outside diameter: NPS 1 pipe has an outside diameter of 1.315". The schedule sets the wall, and a higher schedule means a thicker wall. Pipe dimensions come from ASME B36.10M.
4130 is normally made as mechanical tube to ASTM A519, so a "4130 pipe" requirement is usually met by supplying seamless 4130 tube in the pipe outside diameter and schedule wall. State on the enquiry whether you need pipe dimensions or tube dimensions.
Schedule 40 and Schedule 80 Dimensions in 4130
| NPS | OD (in / mm) | Sch 40 wall (in) | Sch 40 weight (lb/ft / kg/m) | Sch 80 wall (in) | Sch 80 weight (lb/ft / kg/m) |
|---|---|---|---|---|---|
| 1/2 | 0.840" / 21.34 | 0.109 | 0.85 / 1.27 | 0.147 | 1.09 / 1.62 |
| 3/4 | 1.050" / 26.67 | 0.113 | 1.13 / 1.68 | 0.154 | 1.48 / 2.20 |
| 1 | 1.315" / 33.40 | 0.133 | 1.68 / 2.50 | 0.179 | 2.17 / 3.24 |
| 1-1/4 | 1.660" / 42.16 | 0.140 | 2.27 / 3.39 | 0.191 | 3.00 / 4.46 |
| 1-1/2 | 1.900" / 48.26 | 0.145 | 2.72 / 4.05 | 0.200 | 3.63 / 5.41 |
| 2 | 2.375" / 60.32 | 0.154 | 3.66 / 5.44 | 0.218 | 5.03 / 7.48 |
| 2-1/2 | 2.875" / 73.02 | 0.203 | 5.80 / 8.63 | 0.276 | 7.67 / 11.41 |
| 3 | 3.500" / 88.90 | 0.216 | 7.58 / 11.29 | 0.300 | 10.26 / 15.27 |
| 4 | 4.500" / 114.30 | 0.237 | 10.80 / 16.07 | 0.337 | 15.00 / 22.32 |
Weights are theoretical, calculated from the nominal dimensions. Sizes above 5.000" OD are outside our standard tube range and are quoted on request. Individual pages cover Schedule 40, Schedule 80, Schedule 10 and the difference between NB and OD.
When 4130 Is Not the Right Pipe
"Chrome moly pipe" in power plants and refineries usually means ASTM A335 grades such as P11 or P22, made for high-temperature pressure service. That is a different specification from 4130. 4130 pipe-size tube is used for structural and mechanical work, such as frames, shafts, hydraulic cylinder bodies and machined parts. If your drawing calls for A335, do not substitute 4130. See 4130 pressure tubing for where 4130 does and does not fit in pressure work.
Supply and Documentation
Pipe-size 4130 is supplied seamless, to ASTM A519 Grade 4130, with an EN 10204 3.1 mill certificate. It can be cut to length and supplied in mixed sizes in one shipment.
Frequently Asked Questions
Is 4130 pipe the same as 4130 tube?
The material is the same, but the sizing differs. Pipe uses nominal pipe size and schedule; tube uses actual outside diameter and wall. Always state which one your drawing uses.
What is the outside diameter of 2 inch Schedule 40 4130 pipe?
NPS 2 pipe has an outside diameter of 2.375" (60.33 mm) and a Schedule 40 wall of 0.154" (3.91 mm).
Can 4130 replace A335 P11 or P22 chrome moly pipe?
No. A335 grades are made and tested for high-temperature pressure service. 4130 is a structural and mechanical grade and should not be substituted without an engineering approval.
Do you cut 4130 pipe to length?
Yes. Pipe-size tube can be cut to your lengths and supplied with the mill certificate.
Request a 4130 Pipe Quote
Give the NPS and schedule, or the OD and wall, with the quantity.
- NPS and schedule, or OD and wall
- Quantity and lengths
- Standard and certificate
- Delivery country
Get a Quote
Send your sizes and quantities by email or WhatsApp. The product and this page are filled in for you.
Email: sales@chromolytubing.com
Phone / WhatsApp: +91 96194 06392